Applications

Applications

Passive Fire Protection Across Every Building Type

From hospital corridors to airport terminals, BÖLDT fire doors and fire curtains are specified to meet compartmentation requirements under Approved Document B and BS 9999 across the full range of occupancy types.

EN 1634-1EN 12101-1EN 13501-2EN 16034TÜV SÜD VERIFIED
Hospital corridor requiring fire-rated compartmentation
01BOTH

Application

Hospitals & Healthcare

Hospitals present some of the most demanding compartmentation requirements in the building code — continuous occupancy, non-ambulatory patients, and corridors that double as both circulation and evacuation routes.

Specification Highlights

  • EI 120 fire-rated steel doors at compartment corridor intersections (per BS 9999 / HTM 05-02)
  • Glazed fire doors at nursing stations and ICU corridors for staff sightlines without compromising rating
  • Type 3 fire curtains and 240-minute fixed curtains for atrium and central courtyard compartmentation
  • Hollow metal shaft doors for lift and stairwell enclosures serving patient floors
Commercial high-rise tower facade
02BOTH

Application

Commercial High-Rise

High-rise office and mixed-use towers depend on pressurised escape routes and shaft enclosures that remain fire-tight for the full evacuation period, even under continuous lift and stairwell traffic.

Specification Highlights

  • Hollow metal shaft doors rated EI 120 for lift lobbies and stairwell entrances (per Approved Document B / BS 9999)
  • Automatic fire curtains across atrium voids and double-height lobbies, concealed when not deployed
  • Egress fire curtains at final exit thresholds where evacuation routes pass through compartment lines
  • Steel fire doors at basement-to-occupied-floor access points (EI 120)
Government and institutional building interior
03BOTH

Application

Government & Institutional

Government, judicial and institutional buildings combine large public volumes, complex circulation geometries and strict national compliance requirements under a single roof.

Specification Highlights

  • Accordion fire curtains for curved atriums, stepped auditoriums and raked assembly halls
  • Steel fire doors throughout administrative wings, tested to EN 1634-1 and classified to EN 13501-2
  • Smoke curtains forming reservoirs in central halls connected to SHEV systems
  • Full documentation package (test certificates, EN 13501-2 classification, DoP) for compliance audits
Hotel lobby and guest corridor
04BOTH

Application

Hospitality

Hotels and serviced apartments require fire separation that is consistent with guest-facing finishes, from individual room corridors through to double-height lobby and banquet volumes.

Specification Highlights

  • EI 30 – EI 60 fire-rated, self-closing corridor doors for guest rooms
  • Glazed fire doors at lobby and reception thresholds for visual continuity
  • Up to 120-minute fire curtains across banquet hall and atrium openings for assembly area compartmentation
  • Hollow metal shaft doors for back-of-house service risers and stairwells
Data centre requiring fire-rated compartmentation
05BOTH

Application

Industrial Facilities

Industrial and warehouse buildings need robust, low-maintenance compartmentation for high-bay volumes, basement parking and fire-separating walls between process areas.

Specification Highlights

  • EI 60 – EI 120 fire-separating elements between process and storage areas
  • Smoke curtains for basement and multi-level vehicle parking smoke control
  • Fixed fire curtains for permanent shaft and void closures in service areas
  • Steel fire doors rated to 120 minutes for high-traffic compartment access points
Airport terminal departure hall
06FIRE CURTAINS

Application

Airports & Transport Hubs

Terminal buildings combine vast open volumes, column-interrupted facades and continuous public movement — conditions that call for curtain systems engineered for unconventional openings.

Specification Highlights

  • Accordion fire curtains for column-interrupted facades and stepped terminal roof lines
  • Smoke curtains forming reservoirs across check-in halls and concourses
  • Egress fire curtains at gate-to-concourse thresholds along evacuation routes
  • 240-minute fixed fire curtains for permanent compartmentation of back-of-house service voids

Not Sure Which System Fits Your Project?

Share your building type, occupancy and compartmentation requirements with our technical team for a specification recommendation aligned with Approved Document B and BS 9999.