Certifications

Certifications

Tested, classified and verified to European standards

Every BÖLDT fire door and fire curtain is tested by recognised European laboratories and classified to the standards that UK and European specifiers and approving authorities require.

BS/EN 1634-1BS/EN 12101-1BS/EN 13501-2BS/EN 16034TÜV SÜD VERIFIEDDoP ON REQUEST
EN 1634-1 furnace fire test of a BÖLDT fire curtain

EN 1634-1 furnace testing. Every BÖLDT classification is established by full-scale fire test, not estimated.

Standards & Marks

What each certification covers

Jump to a standard

BS/EN 1634-1

Fire resistance test

The European test method for fire resistance of door, shutter, openable window and curtain assemblies. BÖLDT fire doors and fire curtains are tested to EN 1634-1, establishing integrity and insulation performance for periods up to 240 minutes.

BS/EN 13501-2

Fire classification

The European classification standard. Results from EN 1634-1 testing are expressed as EI, E or EW ratings with a time period in minutes (for example EI 60, EI 120), giving specifiers a directly comparable classification.

BS/EN 12101-1

Smoke barriers

The European product standard for smoke barriers and smoke curtains, covering reliability, durability and the performance of smoke-control components used to protect escape routes and form smoke reservoirs.

BS/EN 16034

Product standard

The harmonised product standard for the fire-resisting and smoke-control characteristics of doorsets, shutters, fire curtains and gates, paired with EN 13241 or EN 14351-1 as the basis for CE / UKCA marking under the Construction Products Regulation.

TÜV SÜD

Independent verification

Fire and smoke curtain assemblies, fabric, head box, guide rails and bottom bar, are independently verified by TÜV SÜD and Efectis, confirming that manufactured products conform to the tested configurations.

Marking / DoP

Construction Products Regulation

Fire safety products placed on the GB and EU markets require UKCA or CE marking with a Declaration of Performance. Contact our technical team for the current marking status and DoP for a specific product.

Compliance Guide

Typical fire-resistance requirements by application

The table below maps common building applications to the relevant UK guidance and the typical classification specified to meet each requirement. Indicative only, confirm against the current Approved Document B, BS 9999 or BS 9991 for the specific building.

Fire origin, containedFire doorsCompartment linesFire curtainFloor opening
FIG. 04Fire compartmentation, building sectionBÖLDT · Not to scale
ApplicationGuidanceTypical classificationRecommended product
Protected stairway enclosuresApproved Document B / BS 9999EI 30 – EI 60Steel Fire Door
Flat entrance doors (residential)FS(E) Regs 2022 / BS 9991FD30S – FD60SSteel Fire Door
Firefighting shafts & lobbiesApproved Document B / BS 9999EI 120Hollow Metal Shaft Door
Compartment walls between occupanciesApproved Document BEI 60 – EI 120Steel / Glazed Fire Door
Hospital compartment intersectionsHTM 05-02 / BS 9999EI 120Steel / Glazed Fire Door
Atrium & large-volume compartmentationEN 1634-1 / BS 9999Up to EI 240Fire Curtains
Smoke control to escape routesEN 12101-1ClassifiedSmoke Curtains
UnprotectedFire spreads uncheckedWith BÖLDT barriersFire held to one compartment
FIG. 07Compartmentation, contained vs unprotectedBÖLDT · Not to scale

Standards Equivalence

Mapping the evidence across frameworks

BÖLDT products are tested and classified to European standards. The table below maps those standards to the UK and Indian frameworks, so evidence can be read against whichever regime applies to your project.

PurposeEurope (EN)United KingdomIndia (legacy)
Fire resistance testEN 1634-1BS 476-20 / -22 (legacy)IS 3614
ClassificationEN 13501-2 (EI, E, EW)BS 476 integrity / insulationIS 3614 rating
Product standard & markingEN 16034 (DoP on request)UKCA status on requestISI licence on request
Smoke controlEN 12101-1BS EN 12101Not applicable

Local Reference

One EN classification, recognised across Europe

BÖLDT products are tested and classified exclusively in accordance with harmonised European standards (EN 1634-1, EN 12101-1, EN 13501-2, and EN 16034). The EI classification established by these standards serves as the benchmark for national fire safety frameworks across the EU, including DIN 4102/MLAR (Germany), ERP/IGH regulations and DTUs (France), CTE DB-SI (Spain), and the Codice di Prevenzione Incendi (Italy). As a result, a single tested and classified BÖLDT product range can be specified across projects in these markets.

Quality Assurance

From raw material to finished assembly

Certification is only meaningful when it reflects what is actually manufactured. Every BÖLDT fire door and fire curtain is produced at our 111,000 sq ft facility using the same materials, processes and tolerances validated in the certified test assemblies, from incoming steel and fabric inspection, through CNC fabrication and powder coating, to final dimensional and functional checks before dispatch.

BS/EN 1634-1BS/EN 12101-1BS/EN 13501-2BS/EN 16034TÜV SÜD VERIFIEDDoP ON REQUEST

Need certification documentation for a submission?

Our technical team can provide test certificates, EN 13501-2 classification reports and Declarations of Performance for your project specification.